For concrete paver joints up to 1" in traditional applications
setting time 1hr
sets above 32°F (0°C)
SUPERSAND BOND is a unique mixture of polymer binders and calibrated sand available in Beige and Slate Grey. The installation of SUPERSAND BOND is almost identical to using regular paver joint sand except for the application of water. Once SUPERSAND BOND sets, it becomes very firm and locks between the paver joints while still retaining flexibility and providing a long lasting, durable jointing material. SUPERSAND BOND is recommended for a variety of uses including pool decks, patios, footpaths, driveways, parking spaces, pavements etc.




Maintenance of paved surface
When maintaining the paver surface, apply Gator Shampoo to clean the entire paved surface including the paver joints. Wash, rinse and remove any residue by using a hose and a watering gun set to shower with the normal maximum water pressure from any residential or commercial building (typically 80 psi/550 kPa).
Moss
SUPERSAND BOND will not cause nor prevent moss, mold or mildew. Moss, mold and mildew are caused by certain on site conditions including excess moisture, shade, absence of ventilation, inadequate cleaning or maintenance, presence of soil or other organic debris left on the product.
Clay Pavers
If used on clay pavers make sure they are 100% dry. Clay pavers tend to hold moisture, which can prematurely activate the SUPERSAND BOND while the sand is being spread over the paver surface, leaving a residue (always apply on a test area before using the SUPERSAND BOND on clay pavers).
Quantity required depends on the shape and size of the concrete pavers as well as the width of the joints.
| Per 50 lb (22.7 kg) bag (Paver 2-3/8” (6 cm) in height) | NARROW JOINTS 1/8” to 3/8” (3-9 mm) | WIDE JOINTS 3/4” to 1” (19-25 mm) |
|---|---|---|
| Beige, Slate Grey | 65-85 sq. ft. (6-7.9 sq.m.) | 22-42 sq. ft. (2-3.88 sq. m.) |
| Product | Size | Units per Pallet |
|---|---|---|
| SUPERSAND BOND – Beige | 50 lb (22.7 kg) | 56 |
| SUPERSAND BOND – Slate Grey | 50 lb (22.7 kg) | 56 |

Maximum joint width: 1″ (2.5 cm)
POLYMERIC SAND REQUIREMENTS
Minimum joint width: 1/8″ (3 mm)
Maximum joint width: 1″ (2.5 cm)
Minimum joint depth: 1 1/2″ (38 mm)
SUPERSAND BOND is recommended for a variety of uses including pool decks, patios, footpaths, driveways, parking spaces, pavements etc. The concrete pavers must be installed on a traditional base system composed of 2 layers. The upper layer can have a maximum of 1 inch (2.5 cm) of bedding sand. The lower layer must have a minimum of 6 inches (15 cm) of crushed stone compacted at 98 % Proctor density. (See diagram below)
Sand or ASTM No. 9 Stone can be used under pavers
NEVER USE SUPERSAND BOND WHEN PAVERS ARE INSTALLED ON A CONCRETE SLAB. INSTEAD, USE GATOR MAXX SAND G2
Spread SUPERSAND BOND with hard-bristle broom. Make sure the SUPERSAND BOND completely fills the joints. Do not use other materials in the joints.
Leave a layer of SUPERSAND BOND on the surface to aid in vibrating and consolidating SUPERSAND BOND into joints. For textured or pre-finished surfaces, we recommend to remove all the sand from the paver or slab surface prior to using the plate or roller compactor
Vibrate the SUPERSAND BOND into the paver joints using a vibratory plate or roller compactor. A rubber pad is recommended. A roller compactor is best for slab installation.
Joints sand level, must be at least 1/8 inch (3 mm) below top of paver’s surface without chamfer or 1/8 inch (3 mm) below the chamfer. It is best to compact in several directions to ensure there are no air gaps or voids in the joints. Repeat steps 1-3 to ensure joints are filled and consolidated. Narrow joints require more care to completely fill.
Sweep off excess SUPERSAND BOND from the paved surface, first with a hard-bristle broom, then a soft bristle broom. Joints sand level, must be at least 1/8 inch (3 mm) below top of paver’s surface without chamfer or 1/8 inch (3 mm) below the chamfer
Shower water on a specific water area of 100 sq. ft. (10 sq. m.), wait no longer than 2 to 3 minutes. Proceed to STEP 8.
Use a leaf blower to remove any excess water remaining on the paver pores and crevices. This blowing action is necessary to help remove any remaining SUPERSAND BOND residue left on paver surfaces from the previous steps. Note : SUPERSAND BOND, sets within 1 hour after water activation at above 32ºF (0ºC) (No rain should occur within 1 hour after water activation).
The water used in steps 7 to 9 will activate a bonding action as well as condensing SUPERSAND BOND in the joints. It is important to water the SUPERSAND BOND a total of 3 times, as per steps 7, 8 and 9. Too little water will not properly activate the SUPERSAND BOND and will reduce the final performance. If steps 7 to 10 are not done properly, a white haze may appear on paver surface after installation. This is due to excess SUPERSAND BOND residue left on paver surfaces. This haze will dissipate over time, or it could be removed by using Gator Clean Efflorescence Cleaner.
Remove existing jointing material. Be careful not to disturb the bedding material under the pavers. Pavers must be completely dry before installing a minimum of 1 1/2’’ (38 mm) deep into the joints. SUPERSAND BOND level, must be at least 1/8 inch (3 mm) below top of paver’s surface without chamfer or 1/8 inch (3 mm) below the chamfer or erosion may occur. The filled and cured polymeric sand joints should never be in direct contact with foot traffic or tires. Follow SUPERSAND BOND installation steps 1 to 10 for a new paver surface.
THE PARTIES AGREE THAT REFUND OF THE PURCHASE PRICE AS STATED IS THE ONLY OBLIGATION OF THE MANUFACTURER. IN ALL EVENTS, THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES OR COSTS WHATSOEVER, (INCLUDING REMOVAL OR REINSTALLATION OF SAND OR PAVERS) DIRECT OR CONSEQUENTIAL. TO THE EXTENT PERMITTED BY LAW, THE MANUFACTURER EXCLUDES ANY IMPLIED WARRANTY OF QUALITY, MERCHANTABILITY OR FITNESS FOR PURPOSE. ALLIANCE DESIGNER PRODUCTS INC. excludes any responsibility whatsoever for the presence of moss, mold, mildew, or similar factors that may occur on the product after its installation. The presence of moss, mold or mildew is caused by the particular on-site conditions, including excess moisture, shade, absence of ventilation, inadequate cleaning or maintenance, presence of soil or other organic debris left on the product after installation. ALLIANCE DESIGNER PRODUCTS INC. excludes any responsibility for use of SUPERSAND BOND for any installation not installed to manufacturer’s specifications and ICPI Tech Spec #2.